Einzelheiten zum vollständigen Inhalt des Kits finden Sie in der nachstehenden Materialliste
Artikelnummer Beschreibung Menge Menge auf lager
02106062 O-Ring,Viton,107.32 x 5.33mm,ISO 100 4 27
320538 O-Ring,Viton,85X5mm 1 4
4070621 O-Ring,Viton,38x3.0mm 4 8
4070420 O-Ring,Viton,24 X 2.5MM 5 20
PL23970504 O-Ring,Viton,55 X 5 MM 2 4
4070333 O-Ring,VIT.19X2.5MM,UNO/DUO1.5 2 8
380050 Ventilsitz 1 6
300215 Gehäusedichtung, Kork,UNO/DUO 250A 1 3
300214 Ringdichtung,UNO250A,DUO250A/255M 2 15
38250019 Dowty-Dichtung,12.7x18x1.5mm 1 11
320525 O-Ring,Viton, 35x 5 mm 2 21
48655900 O-Ring,Viton,44 X 3 MM 1 29
4070542 O-Ring,Viton,32 X 3MM 2 9
PL23970129 O-Ring,Viton,65 X 5 MM 2 9
48656700 O-Ring,Viton,140 X 5 MM 1 9
PL23970419 O-Ring,Viton,125 X 5 MM 3 11
310152 Wellendichtung,Viton,Einfache Lippe 2 12
4070088 O-Ring,Viton,6 x 2.2 mm 7 34
4070259 O-Ring,Viton,15 X 2.5MM 3 34

Allgemeine Produktklassifizierungen

Alternative Produktnummer PKE00016-T
Kompatible Marken Pfeiffer
Produktgruppe DUO
Pumpenmodelle DUO250A
UNO250A
Kategorie Reparatursätze
Unterkategorie Dichtungskits
Ursprungsland US

Oil Sealed, Two Stage Rotary Vane Pumps

  • DUO 120A – standard version
  • DUO 125 (Index B) – standard version
  • DUO 125M – magnetic coupling
  • UNO/DUO 250A – standard version
  • DUO 255M (Index C)  – magnetic coupling

* MC version – Corrosive gas application (with magnetic coupling)

Oil Change:

The maintenance schedule of operating fluid depends on application and location of pump. The oil must be changed if:

  • Ultimate pressure is no longer attainable
  • Oil appears contaminated, milky, or cloudy when viewed through sight glass
  • Oil is discolored

Oil Capacity:

  • DUO 120 - 13 liter
  • DUO 125 - 14 liter
  • UNO 250 - 30 liter
  • DUO 250 - 23 liter
  • DUO 255 - 25 liter

Maintenance Intervals:

Daily:

  • Check operating fluid levels
  • Check for leaks

As required (at least annually):

  • Change operating fluid
  • Disassemble casing, sight glass and pumping system and clean casing outside (without cleaning agent)
  • Clean gas ballast valve & silencer
  • Clean motor fan cap

As required (at least every 2 years):

  • Disassemble the pump, clean & exchange seal and wearing parts

As required (at least every 4 years):

  • Carry out work in accordance with maintenance and additionally
    • Change vanes
    • Change valves, springs, and sight glass
    • Change silencer nozzle
    • Check coupling and exchange is necessary